  • Defects in the zinc coating of galvanized cable trays

    Defects in the zinc coating of galvanized cable trays

    Defects that impair functionality, such as bare spots, blisters, rough nodules, or excessive zinc dross, are not permitted. Requirements for electro-galvanized trays are mainly defined in GB/T 26941. Zinc Coating Thickness Requirement The standard stipulates that the zinc...

    [PDF Version]
  • Should the bottom of the electrical distribution box on the construction site be sealed off

    Should the bottom of the electrical distribution box on the construction site be sealed off

    Switchboards must have a cut out (not sharp to prevent cables being cut, ie by providing brushing or plastic hose around it) in the bottom plate to allow safe entry of electrical leads with the door closed. A label must be fixed to the switchboard stating 'KEEP CLOSED – RUN...

    [PDF Version]
  • Height of the bottom of the network cabinet from the ground

    Height of the bottom of the network cabinet from the ground

    The cabinet is installed 36” from the bottom of the cabinet to the ground and is always secured to the pole on the downstream side of traffic unless otherwise approved. Some standard dimensions have become. Server rack cabinets come in different sizes, and the three main...

    [PDF Version]
  • Fiber optic cable with PVC coating

    Fiber optic cable with PVC coating

    PVC Compound can increase the mechanical strength and abrasion resistance of optical fiber cables, improving their tensile strength and durability, and reducing the rate of fiber damage during installation and use. Polyvinyl Chloride (PVC) Fiber Optic Cable Assemblies are...

    [PDF Version]
  • Openings on the bottom of the cable tray

    Openings on the bottom of the cable tray

    A ventilated tray has openings in the bottom of the tray, allowing some air circulation around the cables, water drainage, and allowing some dust to fall through the tray. Small cables may exit the tray through the ventilation openings, which may be either slots or holes...

    [PDF Version]
  • Fire-retardant coating thickness of cable trays

    Fire-retardant coating thickness of cable trays

    Recommended film thickness: ~2. ~ 3 days (20 °C/65 % RH) Extensive cleaning of cables is not required. Most EPC specifications narrow the choice to two mainstream solutions: fire wrap systems (encapsulation) and intumescent fire-resistant coatings (reactive coatings). Both...

    [PDF Version]