Fibre Optic Overhead
  • How to connect the ground wire to the fiber optic cable junction box

    How to connect the ground wire to the fiber optic cable junction box

    Run a minimum 14 AWG copper grounding wire (or as specified by local code) from the bonding clamp to the nearest grounding electrode or equipment grounding bus. Keep this conductor as short and direct as possible — avoid sharp bends that increase impedance. Follow these steps...

    [PDF Version]
  • What kind of wire cutter is best for fiber optic patch cords

    What kind of wire cutter is best for fiber optic patch cords

    Kevlar scissors are specifically designed to cut through Kevlar or aramid yarn strength members in fiber optic cabling. We keep them in stock in our store because they are super durable and hold up under extreme use. We compare their core strengths, from ultra-precise...

    [PDF Version]
  • Ground wire at the corner of the distribution box

    Ground wire at the corner of the distribution box

    26 mm 2 (10 AWG) ground wire must be used, and in all other markets a 6 mm 2 must be used. Power from factory ground must be installed by a qualified electrician. Grounding of the units: Attach a ground wire from one of. Today, we're diving deep into the world of distribution...

    [PDF Version]
  • Fiber optic cable without steel wire support

    Fiber optic cable without steel wire support

    Metallic Aerial Self-Supporting (MASS) Cable is an alternative solution used for installing optical cable on medium and high voltage power lines. It is typically used when the existing phase or ground wire replacement is not possible or economical. MASS cable is a compact...


  • Fiber optic patch panel grounding wire diameter

    Fiber optic patch panel grounding wire diameter

    Although the NEC does allow a minimum size of 14 AWG (minimum) for the size of the grounding conductor, 6 AWG is preferred to allow for both grounding and bonding purposes in compliance with ANSI/TIA/EIA-J-STD-607 and the NEC. Alternatively, an insulating joint or equivalent...

    [PDF Version]
  • Is it easy to ground the neutral wire of a distribution box

    Is it easy to ground the neutral wire of a distribution box

    26 mm 2 (10 AWG) ground wire must be used, and in all other markets a 6 mm 2 must be used. Confusion often arises when connecting the neutral and ground conductors within a breaker box, as their proper handling depends entirely on the panel's location within the electrical...


  • Does the plastic distribution box lack a ground wire

    Does the plastic distribution box lack a ground wire

    Metal boxes are directly connected to the grounding conductor (bare copper or green wire), effectively grounding any devices mounted to them. Plastic boxes, however, do not conduct electricity, so they cannot be directly grounded in the same manner. It's crucial to understand...

    [PDF Version]