The bridge blockage point is typically located at the bridge opening where flow contracts upstream and expands downstream, with the direction of flow from upstream to downstream determining the contraction and expansion zones.

Understanding the Blockage Location

In hydraulic modeling, a bridge blockage is considered at the point where the flow is constricted by the bridge structure, piers, or debris. The upstream side of the bridge experiences flow contraction, where water is funneled into the bridge opening, while the downstream side experiences flow expansion, where water spreads back into the channel or floodplain. The blockage point is therefore oriented in the direction of flow, from the upstream contraction reach toward the downstream expansion reach.

Modeling Considerations

Contraction Reach (Upstream): This is the area where water is forced into the bridge opening. Energy losses here are represented by a contraction coefficient, and ineffective flow areas are often defined to exclude overbank regions that do not contribute to active flow. Expansion Reach (Downstream): After passing through the bridge, water expands back into the channel.

Losses are represented by an expansion coefficient, and the active flow area may be larger or smaller than the bridge opening depending on water surface elevation. Piers and Obstructions: Piers or partial blockages reduce the effective flow area. The energy loss depends on the ratio of obstruction area to total bridge opening, the shape of the obstruction, and its angle relative to flow.

Practical Placement of Blockage Points

For modeling purposes, the blockage point is generally placed at the bridge opening, with upstream and downstream cross sections defined to capture contraction and expansion effects. In HEC-RAS, for example, two cross sections upstream and two downstream are used to compute energy losses, and ineffective flow areas are set to ensure only the active flow through the bridge is considered. In Flood Modeller, the bridge unit allows simulation of partially blocked openings and associated headloss within a single structure unit.

Summary

The direction of the bridge blockage point follows the natural flow from upstream to downstream. The blockage is located at the bridge opening, affecting the contraction reach upstream and the expansion reach downstream. Proper modeling requires defining ineffective flow areas, contraction and expansion coefficients, and accounting for piers or debris that reduce the effective flow area.

This ensures accurate simulation of water levels, velocities, and energy losses around the bridge.

Research context

Reference summary

TUFLOW 2D Hydraulic StructuresThe obstruction to flow can be a source of substantial energy loss. In order to appropriately model the energy loss due to a.

From reference to enquiry

Questions for your project

Use these editorial prompts alongside the linked excerpts. They identify items to confirm for your project.

Detailed reading / connection to installation

Fiber connection and distribution references

Direction of the bridge blockage point
Equipment illustration / verify against the selected product

TUFLOW 2D Hydraulic Structures

The obstruction to flow can be a source of substantial energy loss. In order to appropriately model the energy loss due to a bridge in HEC-RAS, there are some things you should know.

Blocked Obstructions

Blocked areas are used to identify areas where a cross section should not have conveyance based on a physical obstruction built in the floodplain but that is not represented in the terrain model.

Modeling Bridges Inside 2D Flow Areas

The 1D cross sections and bridge information are used to compute the family of rating curves, but the curves are only used to obtain the momentum force loss through the bridge opening. This...

HEC-RAS Bridge Modeling

The Bridge Methodology data panel allows the user to define which computational methods HEC-RAS will use at a bridge opening. The user can also select the bridge opening types and bridge pier

5.7 Structures | TUFLOW Classic/HPC User Manual 2025.2

The flume experiments in the ''Afflux at Arch Bridges'' (HR Wallingford, 1988) were done using medium to high bridge blockages (20%~70%), and this approach can generate extremely high velocity when the

Hydrodynamic Effects of Flash Floods Considering the Bridges and

Furthermore, the increasing blockage ratios at bridge B2 during multiple return periods exacerbated the impacts on flood elements, consequently amplifying the disaster of flash floods. This

Blockage at cross-drainage hydraulic structures – Advances,

Blockage of cross-drainage hydraulic structures is a significant concern in water resources and civil engineering projects, particularly in urban areas experiencing increased debris

Bridge Afflux Predictions Using the Lattice Boltzmann Method

Blockage ratio, as one of the key influencing factors for bridge afflux, is defined as the ratio of blockage area to the whole area of the structure in front elevation; Skewness is defined as the

Estimation on afflux of bridge on plain rivers related to blockage

On this basis, this article presented a parametric optimization formula based on blockage ratio and Froude number to estimate afflux of rectangle bridge piers with relatively low blockage ratios on plan

5.7 Structures | TUFLOW Classic/HPC User Manual 2025.2

5.7 Structures Hydraulic structures in the 1D domain are modelled by replacing the momentum equation with standard equations describing the flow through the structure. The structures available are

Blockage of Cross Drainage Hydraulic Structures: Emerging Role of

In the global context of hydrology world, the blockage has not been treated as a significant issue; in the local context of Australia, blockage of cross drainage structures is a

TUFLOW 2D Hydraulic Structures

2D Structure Modelling Theory The theory behind the modelling of energy losses and affluxes of hydraulic structures is presented in the following webinars by Bill

HDS7

= acceleration, ft/s2 (m/s2) = pier width, ft (m) = projected pier width for skewed piers, ft (m) = area, ft2 (m2) = area of an element, ft2 (m2) = area of a pier projected in the direction of flow, ft2 (m2) = area

Cross-sectional blockage effect on the drag force of a scaled round

A flume testing program was carried out to illustrate the cross-sectional blockage effect under different inflow directions. CFD numerical simulations were then conducted to understand the

Defra/Environment Agency Flood and Coastal Defence R&D Programme

31 1 INTRODUCTION This review paper has been prepared as a mechanism for feeding information into the Environment Agency R&D Scoping Study into the Hydraulic Performance of Bridges and Other

Afflux-Blockage Ratio Relationship | Download Scientific Diagram

Download scientific diagram | Afflux-Blockage Ratio Relationship from publication: Bridge Afflux Predictions Using the Lattice Boltzmann Method | The maximum water surface change just upstream

Empirical analysis of backwater level due to skewed bridge

A simple empirical method is proposed for computing the backwater level for different bridge shapes and crossings in compound channels. A series of parametric studies was conducted

Hydrodynamic effects of debris blockage and scour on masonry bridges

Debris blockage is cited as one of the primary causes of bridge failures in the UK and around the world. Masonry bridges, many of which are valuable historical as-sets, are particularly vulnerable to debris